The function of anti-static ESD cleanroom wiper
The function of anti-static ESD cleanroom wiper
What is an anti-static ESD cleanroom wiper?
ESD cleanroom wiper is low-dust and anti-static, laser edge sealing prevents dust, and can be used multiple times; ESD cleanroom wiper is suitable for semiconductor chips, microprocessors, semiconductor assembly and other production lines. Swwip wholeheartedly creates the best anti-static and dust-free wiping cloth solutions for customers.
The anti-static ESD cleanroom wiper is made of 100% polyester double-woven, with a soft surface, easy to wipe sensitive surfaces, and does not lose fibers when rubbed, and has good water absorption and cleaning effects.
Cleaning and packaging products are completed in the ultra-clean room.
The ESD cleanroom wiper edge banding options generally include: cold cutting, laser edge banding, and ultrasonic edge banding. Microfiber dust-free cloth is generally sealed with laser and ultrasonic.
Static electricity is an objective natural phenomenon, which can be generated in many ways, such as contact and friction. It is characterized by high voltage, low power, low current and short action time. Static electricity is a kind of static charged charge. Most of the static electricity is usually caused by friction and separation. Friction causes heat, which makes the molecules in the material active, and then the two substances separate. It is possible for electrons to flow from one substance to Electrons transported by another substance.
During electron transfer, a lack or excess of electrons can generate an electric field, which is known as static electricity. The amount of this electrostatic field depends on the friction or separation of substances, depending on the amount of friction and dispersion, and the relative humidity of the surrounding environment.
A material that can transfer electrons (or charge) between atoms is called a conductor. Substances that cannot transfer electrons (or charges) are called insulators. Whether it is a conductor or an insulator, it will be charged under the action of static electricity. Factors such as body movement, contact, separation, friction, and induction can generate static electricity of thousands of volts or even tens of thousands of volts.
Static electricity can cause serious harm in many ways.
Friction and human static electricity are two major hazards in the electronics industry.
The main measures are: electrostatic protection, dissipation, neutralization, humidification, shielding and grounding.
Anti-static wrist straps, ankle straps, work clothes, shoes and socks, hats, gloves or finger cots constitute the human body's electrostatic protection system, which has the functions of anti-static leakage, neutralization, and shielding.
Usage:
1. Semiconductor wafers, microprocessors, etc.;
2. Semiconductor assembly lines;
3. Disc drives, composite materials;
4. LCD display products;
5. Circuit board production lines;
6. Precision instruments;
7. Optical products;
8. Aviation industry;
9. PCB products;
10. Medical equipment;
11. Laboratory;
12. Dust-free workshop and production line.
(1) As the most important product in industrial production, ESD cleanroom wiper is different from ordinary wipes. Only when it is used correctly can the product exert its maximum effectiveness.
(2) First of all, when using or disassembling, dust-free gloves and masks must be carried. However, for high-end leanroom wiper, the packaging should be unpacked in a clean environment when used, and the packaging bag should be cleaned before unpacking, especially the opening must be kept clean.
(3) When scrubbing, wrap the four sides of the dust-free cloth inside, and it is not suitable to wipe with the edge of the ESD cleanroom wiper. It can be wiped with solvent or used directly.
(4) Finally, during use, the ESD cleanroom wiper must be kept flat and cannot be rubbed. When moving and wiping, try to make the cloth surface and the wiping surface fully contact, and also ensure that the same direction is wiped, and repeated wiping is not allowed.
Related News
Swwip® Industrial Lint-Free Blue Dry Wipes Roll – Reliable Solution for High-Performance Cleaning 2026-04-03 0
Why use 70 percent isopropyl alcohol wipes for cleaning? 2024-12-11 0What kind of cloth is the cleanroom lint free microfiber cleaning cloth?
2024-09-10 48
Cleanroom Microfiber Cleaning Wipes: Key Cleaning Tools in High-Clean Environments 2024-07-24 82Swwip cleanroom non woven cleaning wipes
2024-06-13 98
Applications of industrial wiper roll in industrial production 2024-04-18 137
Sterile Cleanroom Wipes - ideal choice for the pharmaceutical and food industry 2024-03-13 171How to test the quality of cleanroom wipers?
2024-01-11 154The Importance of Keeping a Cleanroom Clean
2023-12-06 253
Characteristics of cleanroom lint free cleaning wipes 2023-11-16 176
How to choose the suitable cleanroom wipes? 2023-10-17 248
What do cleanroom wiper do? 2023-09-14 198
How to clean a sterile cleanroom? 2023-08-09 222
About 3000 series sub-microfiber cleanroom wipes 2023-07-20 296
How to maintain the performance of microfiber cleanroom wiper? 2023-07-11 248
How to distinguish the level or class of dust-free cleanroom wiper? 2023-06-26 278How to judge the cleanliness of the cleanroom wiper?
2023-05-24 305What does the gram/square meter weight of the cleanroom wipes refer to? what does it have to do with quality?
2023-05-12 266
The difference between cleanroom wiper and cleanroom paper 2023-04-27 328
About Swwip® Microfiber Cleanroom Wipes 2023-04-19 242